BIOWAY brand urine strip reader BW-300

图片
BW-300 urine analyzer Specification ●Measurement principle: Artificial intelligence + computer vision technology  ●Scope of application: 10, 11, 12, and 14 parameters test strips compatible  ●Test items: Glucose (GLU), Bilirubin (BIL), Ketone (KET), Specific gravity (SG), pH, Blood (BLD), Protein (PRO), Urobilinogen (URO), Nitrite (NIT), Leucocyte (LEU), Ascorbic acid (VC), Creatinine (CRE), Calcium ion (CAL), MAL  ●Data storage: Large-capacity memory. Can store millions of test results, can query the test result according to the record numbers  ●Display: 7-inch large screen display, touch operation.  ●Peripheral: Reserved RS232 interface, WIFI, network interface, external urine sediment analysis system, hospital management software (HIS, LIS)  ●Voltage: AC 100~240V ± 10%, 50-60Hz, safe and reliable  ●Test speed: 514 samples/hour  ●Printing method: Built-in high-speed thermal printer  ●Working Environment: 15-35 °C, Humidity ★. Using embedded LINUX operating system, ha

bw 2000 urine sediment analyzer video BIOWAY

图片

CMEF 2019 invitation Letter

图片
Dear friend We will attend CMEF shanghai 2019, May 14-17. Will you come? If yes, hope we could have honor to meeting you at our booth NO. H3B02 (We- BIOWAY is a manufacturer of urine strips, urine analyzers and urine sediment analyzers.) Looking forward to your reply, to make an meeting schedule. Best wishes Rita Wu  BIOWAY    Bioway Biological technology Co.,Ltd Tel: +86 516 87989109 Cell/WhatsApp: +86 150 6201 7525 Email:  rita@bioway.com.cn      bioway11 @gmail.com    Web:    www.bioway.com.cn    /   www.bioway-urinalysis.com Skype: bengbeng867     Wechat :wufeng_8068 

Bioway successfully exhibited at Medlab Dubai 2019

图片
 Bioway successfully exhibited at Medlab Dubai 2019 From this Feb 4th to 7th, 2019, Bioway successfully exhibited at Medlab Dubai 2019 with our hot sale and new models of urinalysis products. On the exhibition, we displayed BW-200 semi-auto urine analyzer, BW-500 semi-auto urine analyzer and multi-parameter urine reagent strips. The products we exhibited attracted visitors from all over the world, including the distributors, doctors and scholars etc. The new model BW-300 semi-auto urine analyzer is a big focus. It is highly praised by distributors from India, Pakistan, Bangladesh, UK, Germany, Hungary etc because of its unique design and good performance. Many customers showed great interest in it even it is not launched into market yet. The exhibition is a big success for Bioway. It offers us a chance to meet old customers to strenghen our cooperative relationship, also provides us a platform to show our new products and to know more new clients. Bioway will keep moving. W

Interpretation! The difference between calibrators, standards and controls

图片
First, the difference in definition 1. Calibrator: The calibration for the test item used for quantitative detection is a reference material with the value of the independent variable used in the calibration function. It usually contains 2 to more concentration levels. 2, quality control: used to check the performance of analytical instruments or methods, is a stable substance used to verify the performance of analytical instruments or methods. 3. Standard: A substance having a determined characteristic value for evaluating the measurement method. Including national reference products and internal reference materials, it can be used for quality control of main raw materials, production process and determination of reaction system, product release, registration inspection, supervision and inspection. Second, do you need to register? 1. Calibrator: Generally, it can be combined with the matching reagent to apply for registration, or it can be applied for registration separa

urine test strip - Visual urine test strip, Manual urine test strip, Bioway brand

●L eukocytes :  The detection of white blood cells in the urine suggests a possible UTI. Expected result : Negative ●Nitrite :   Screening for possible asymptomatic infections caused by nitrate-reducing bacteria – Suggesting a possible UTI.  Note : These two parameters (Leukocytes and Nitrite) are commonly used to screen for possible Urinary Tract Infection (UTI) Expected result : Negativ ●Urobilinogen :   the presence of excreted urobilinogen suggests a possible deterioration of liver functions. Urobilinogen is the breakdown product of bilirubin  Expected result: less than 17 µmol/l (< 1mg/dl) ●Protein :   This test is usually run to screen for kidney disease.  Protein in the urine is called Proteinuria. Expected result: Negative ●pH :   Measures the acidity in your urine which may be a sign of kidney stones. Your pH varies during the day going from more acid in the am to more alkaline in the pm. Expected result : Low ●Blood :  Blood in the urine is calle

BIOWAY URINE CHEMISTRY ANALYZER- BW-200

图片
BIOWAY URINE CHEMISTRY ANALYZER -  BW-200 ●Measurement principle:  Ultra-high brightness cold light source, reflectometry principle  ●Scope of application:  10, 11 and 12 ●Measurement items:  Glucose (GLU), Bilirubin (BIL), Ketone ( KET), Specific gravity (SG), pH, Blood (BLD), Protein (PRO), Urobilinogen (URO), Nitrite (NIT), Leukocyte (LEU), Ascorbic acid (VC), Creatinine (CRE ), Calcium (CAL) and Microalbumin (MAL)  ●Test Speed:  60-120 samples/Hour  ●Test Strip Type:  Open test strips  ●Record Method:  Thermal print/LCD display  ●Detection Wavelength:  525nm-660nm  ●Language Selection:  Chinese, English  ●Working Environment:  15°C~35°C, Humidity<85% ●Power:  50VA ●Net Weight:  ≤3Kg  ●Data Communication:  RS232 interface, external urine sediment analysis system, hospital management system  ●Data Storage:  2000 test results can be stored, can be queried according to the record label  ●Report method:  Select internati